Quadro Quadro4x Guia de Instalação Página 38

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 41
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 37
QuadroE1/T1 Manual-I: Installation Guide Appendix: Checking the Connections
Appendix: Checking the Connections
If the system seems to work incorrectly even when all cables are connected properly, it may
be helpful to Start Network Diagnostics: The WAN link, IP configuration, gateway, DNS
server, and STUN-NAT (if used) will all be checked.
To start diagnostics, open the System's menu item Diagnostics and click Start Network
Diagnostics.
In the case of a successful test, the output of the system looks as follows:
Basic Tests:
Checking for physical link: WAN link ok
Checking IP configuration: dynamically via DHCP Client
DHCP Client is running
Checking internet connectivity (ICMP ping):
Gateway: reached
Primary nameserver: reached
Secondary nameserver: not configured
www.epygi.com: reached
STUN Network Address Translation (NAT) Check:
External visibible address: 212.126.210.179
Detected NAT type : Restricted cone
Performing MTU Discovery:
preparing system
Sending UDP Datagram of size 1500 got answer
clean up
Largest usable MTU size is: 1500 Bytes
Test successful.
QuadroE1/T1; (SW Version 2.4.x) 37