QuadroE1/T1 Manual-I: Installation Guide Configuring the QuadroE1/T1
Editing the E1/T1 Trunk
Select Network as your Interface Type if your QuadroE1/T1 is connected to a PBX, other-
wise choose User.
Next, you are required to enter the Signaling type (CAS or CCS), adjust the correct inter-
face type (E1 or T1), and specify the requested settings of the selected interface type. The
appropriate parameters should be requested from the service provider or in case of connect-
ing to a PBX - according to the settings in the PBX manual.
CAS signaling allows use of the same timeslot both for voice and data transmission. CCS
signaling uses a single timeslot for signaling data transmission for the whole trunk, all other
timeslots are used for voice transmission.
E1, the European system, enables 32 (if CAS is used) or 30 (if CSS is used) timeslots to be
used; T1, the US system, enables 24 timeslots (if CAS is used) and 23 (if CSS is used).
Please Note: Modifying the E1/T1 trunk settings may lead to some broken routes in the Lo-
cal Call Routing Table.